Forward Converter Calculator
Calculate duty cycle, power, input current, and switching period for an isolated forward DC-DC converter.
About forward converter design
Forward converter examples
| Design inputs | Calculated values | Application |
|---|---|---|
| 24 V to 5 V, N 4, 2 A, η 0.85 | 83.333333% duty, 10 W output | Low-power isolated supply |
| 48 V to 12 V, N 3, 5 A, η 0.88 | 75% duty, 60 W output | Medium-power supply |
| 400 V to 24 V, N 12, 10 A, η 0.92 | 72% duty, 240 W output | High-voltage input design |
How to calculate a forward converter
- Enter the minimum operating input voltage and required output voltage.
- Enter the primary-to-secondary transformer turns ratio and output current.
- Express efficiency as a decimal, then enter switching frequency in hertz.
- Select Calculate and check duty cycle, power, current, and switching period.
Frequently asked questions
How is forward converter duty cycle calculated?
Multiply output voltage by the primary-to-secondary turns ratio, then divide by input voltage. The ideal result must be checked against the controller and transformer reset limits.
Should efficiency be entered as a percent?
Enter efficiency as a decimal, such as 0.85 for 85 percent. The calculator uses it to estimate input power and average input current.
Why can the calculated duty cycle be impractical?
The ideal equation omits reset time, switching losses, and semiconductor drops. A real converter needs duty-cycle margin to reset the transformer core safely.
Is average input current the switch peak current?
No, the displayed input current is a steady-state power-balance average. Peak switch current also includes ripple and magnetizing current and requires a detailed power-stage design.
What does switching frequency change?
A higher frequency shortens each switching period and can reduce magnetic component size. It can also increase switching and core losses, so frequency is a design tradeoff.